{"id":12880,"date":"2021-06-21T03:59:00","date_gmt":"2021-06-20T19:59:00","guid":{"rendered":"https:\/\/rewa.tech\/iphone-8-plus-wont-turn-on-with-large-current\/"},"modified":"2024-05-10T15:29:07","modified_gmt":"2024-05-10T07:29:07","slug":"iphone-8-plus-wont-turn-on-with-large-current","status":"publish","type":"post","link":"https:\/\/rewa.tech\/es\/iphone-8-plus-wont-turn-on-with-large-current\/","title":{"rendered":"iPhone 8 Plus Cannot Start Up With Large Current"},"content":{"rendered":"<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><b><span style=\"font-family: Calibri; font-size: 15pt;\">Fen\u00f3meno del mal funcionamiento<\/span><\/b><b><span style=\"font-family: Calibri; font-size: 15pt;\"><\/p>\n<p><\/span><\/b><\/p>\n<p class=\"MsoNormal\" style=\"text-autospace: ideograph-numeric; mso-pagination: none; line-height: 20.0000pt; mso-line-height-rule: exactly;\"><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\">The phone just can<\/span><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\">'<\/span><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\">t be turned on suddenly. <\/span><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\"><\/p>\n<p><\/span><\/p>\n<p class=\"MsoNormal\" style=\"text-autospace: ideograph-numeric; mso-pagination: none; line-height: 20.0000pt; mso-line-height-rule: exactly;\"><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\">And with a large current once gets connected with the DC power supply.<\/span><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\"><\/p>\n<p><\/span><\/p>\n<p class=\"MsoNormal\" style=\"text-autospace: ideograph-numeric; mso-pagination: none; line-height: 20.0000pt; mso-line-height-rule: exactly;\"><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\"><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><b><span style=\"font-family: Calibri; font-size: 15pt;\">Soluci\u00f3n de problemas<\/span><\/b><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><b><span style=\"font-family: Calibri; font-size: 15pt;\"><\/p>\n<p><\/span><\/b><span style=\"font-family: Calibri; font-size: 12pt;\">For the issue&nbsp;<\/span><span style=\"font-family: Calibri;\"><span style=\"font-size: 16px;\">iPhone 8 Plus Cannot Start Up With a Large Current.&nbsp;<\/span><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">According to the experience of repair, we can find out the fault of the component with the&nbsp;<\/span><span style=\"font-family: Calibri; font-size: 12pt;\">rosin detecting&nbsp;<\/span><span style=\"font-family: Calibri; font-size: 12pt;\">method.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">Soak some rosin with soldering iron and then smoke rosin on the surface of the relevant components on PP_VCC_MAIN. Apply a proper power voltage and find the rosin on C2859 melted.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">Judging by this, the fault is related to C2859. Because C2859 is a filter capacitor, so we can remove it directly.<\/span><b><span style=\"font-family: Calibri; font-size: 15pt;\"><\/p>\n<p><\/span><\/b><span style=\"font-family: Calibri; font-size: 12pt;\"><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/rewa.tech\/wp-content\/uploads\/2024\/04\/iPhone_8_Plus_Cannot_Start_Up_With_Large_Current_C2859.png\" alt=\"iPhone 8 Plus Cannot Start Up With Large Current\" width=\"301\" height=\"341\" title=\"\">&nbsp; &nbsp;&nbsp;<\/span><img decoding=\"async\" src=\"https:\/\/rewa.tech\/wp-content\/uploads\/2024\/04\/iphone-8-plus-wont-turn-on-with-large-current-sintl.png\" alt=\"\" width=\"418\" height=\"351\" title=\"\"><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\"><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\">After that, got the motherboard mounted and display assembly installed, and test again,&nbsp;<\/span><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\">all function is normal.&nbsp;<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 12.0000pt; mso-font-kerning: 1.0000pt;\">Problem resolved.<\/span><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; font-size: 10.5000pt; mso-font-kerning: 1.0000pt;\"><\/p>\n<p><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\"><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\"><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><strong><span style=\"font-family: Calibri; font-size: 12pt;\">Repair tips<\/span><\/strong><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">For issues like large current once connected with DC power supply<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">Normally it&#8217;s caused by the related power rail which before press power button with some power leakage.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">The rosin inspection method or thermal camera detection method is quite easy to find out the shorted components.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\"><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">And as mentioned, after finding out the shorted component, just replace it or tick it off directly.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\">(Normally, the filter type capacitor can be ticked off directly)<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\"><\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; text-justify: inter-ideograph;\"><span style=\"font-family: Calibri; font-size: 12pt;\"><\/span><\/p>\n<p class=\"MsoNormal\"><a href=\"https:\/\/academy.rewa.tech\/courses\/iphone-x-logic-board-repair-course\"><b><u><span class=\"15\" style=\"font-family: Calibri; color: #0000ff; letter-spacing: 0pt; font-size: 16pt; background: #bfe6ff;\">Curso de reparaci\u00f3n de la placa base del iPhone X<\/span><\/u><\/b><\/a><span style=\"mso-spacerun: 'yes'; font-family: Calibri; mso-fareast-font-family: \u5b8b\u4f53; mso-bidi-font-family: 'Times New Roman'; font-size: 10.5000pt; mso-font-kerning: 1.0000pt;\"><\/p>\n<p><\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Malfunction Phenomenon The phone just can&rsquo;t be turned on suddenly. And with a large current once gets connected with the DC power supply. Troubleshooting For the issue&nbsp;iPhone 8 Plus Cannot Start Up With a Large Current.&nbsp; According to the experience of repair, we can find out the fault of the component with the&nbsp;rosin detecting&nbsp;method. Soak [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":12881,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"fifu_image_url":"","fifu_image_alt":"","footnotes":""},"categories":[780],"tags":[],"class_list":["post-12880","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-iphone-repair-cases"],"_links":{"self":[{"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/posts\/12880","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/comments?post=12880"}],"version-history":[{"count":0,"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/posts\/12880\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/media\/12881"}],"wp:attachment":[{"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/media?parent=12880"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/categories?post=12880"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rewa.tech\/es\/wp-json\/wp\/v2\/tags?post=12880"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}